* Updating the firmware will delete all code installed on the myRIO. Instructions on how to update the BIOS and firmware on the myRIO:
Tools required:
- LabVIEW 2014 (fall) or later
- NI MAX
How to check the version of the LabVIEW Real-Time is installed.
- Plug in myRIO
- The LabVIEW USB monitor launches (fig 1)
- If Labview is disabled, then Real-time needs updating
- Click "configure NI myRIO"
- Allow Silverlight to run in the browser, required the myRIO web interface to run (fig 1b)
- Under "Software Management" it will display which version of the "LabVIEW Real-Time" is installed and which version of LabVIEW to use (fig 2)
Update BIOS and Real-Time instruction guide.
- Launch NI MAX
- Under remote systems select myRIO and select update firmware (BIOS) (fig 5a-g)
- Browse and select the cfg file e.g. myRIO-1900_2.0.0f2.cfg
- Click Begin Update
- Enter username admin and no password (default)
- It will begin transferring/flashing the firmware image
- Once restarted, you can now update the LabVIEW Real-TIME
- Launch NI MAX
- Right click on software under the remote systems (fig 6) and select "Add/Remove Software"
- Select latest version of real-time (fig 6b)
- Select optional add-ons (fig 6c-d)
- Update completed, now the NI myRIO USB Monitor allows you to launch LabVIEW (fig 7)